Integrated Current Sensor
Hall current sensor NSM201x series of NOVOSENSE is mainly based on the Hall effect principle, using an isolated way to convert the current within ±100A into linear voltage output, which is suitable for a variety of isolated current sampling occasions, including current detection of MPPT (maximum power point) tracking on DC input side of photovoltaic cluster inverter, current sampling of busbar and bridge arms in industrial inverter parts, power supply of UPS and server, and isolated current sampling in charging pile.
View All Products
show 17 devices
Part Number | ECAD Model | Primary resistance (mΩ) | Dielectric strength (Vrms) | Creepage (mm) | Power supply (V) | Bandwidth (KHz) | Response time (us typ.) | Working temperature (℃) | Offset (V) | Sensitivity (mV/A) | Current sense range (A) | Packaging | Application grade |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NSM2019-Q1 |
|
0.27 | 5000 | 8.2 | 3.3 | 320 | 1.5 | -40~150 | 1.65 | 16.5 | ±80 | SOW10 | Automotive |
CCC |
|
0.85 | 5000 | 8 | 3.3 | 240 | 2.2 | -40~125 | 50%VCC | 66 | ±20 | SOW16 | Industrial |
dDD |
|
0.85 | 5000 | 8 | 5 | 240 | 2.2 | -40~125 | 50%VCC | 66.67 | ±30 | SOW16 | Automotive |
NSM2011 |
|
0.85 | 5000 | 8 | 3.3 | 240 | 2.2 | -40~125 | 50%VCC | 66 | ±20 | SOW16 | Industrial |
NSM2011-Q1 |
|
0.85 | 5000 | 8 | 5 | 240 | 2.2 | -40~125 | 50%VCC | 66.67 | ±30 | SOW16 | Automotive |
NSM2012 |
|
1.2 | 3000 | 4 | 3.3 | 400 | 1.5 | -40~125 | 50%VCC | 660 | ±2 | SOP8 | Industrial |
NSM2012-Q1 |
|
1.2 | 3000 | 4 | 5 | 400 | 1.5 | -40~125 | 10%VCC | 400 | 10 | SOP8 | Automotive |
NSM2013 |
|
0.85 | 5000 | 8 | 5 | 240 | 2.2 | -40~125 | 2.5 | 100 | ±20 | SOW16 | Industrial |
NSM2013-Q1 |
|
0.85 | 5000 | 8 | 3.3 | 240 | 2.2 | -40~125 | 1.65 | 20.3 | ±65 | SOW16 | Automotive |
NSM2015 |
|
0.85 | 5000 | 8 | 3.3 | 320 | 1.5 | -40~125 | 1.65 | 132 | ±10 | SOW16 | Industrial |
NSM2015-Q1 |
|
0.85 | 5000 | 8 | 5 | 320 | 1.5 | -40~125 | 2.5 | 100 | ±20 | SOW16 | Automotive |
NSM2016 |
|
1.2 | 3000 | 4 | 5 | 380 | 1.5 | -40~125 | 2.5 | 100 | ±20 | SOP8 | Industrial |
NSM2016-Q1 |
|
1.2 | 3000 | 4 | 5 | 380 | 1.5 | -40~125 | 0.5 | 80 | 50 | SOP8 | Automotive |
NSM2017 |
|
0.85 | 5000 | 8 | 3.3 | 320 | 1.5 | -40~125 | 50%VCC | 33 | ±40 | SOW16 | Automotive |
NSM2017-Q1 |
|
0.85 | 5000 | 8 | 3.3 | 320 | 1.5 | -40~125 | 50%VCC | 33 | ±40 | SOW16 | Automotive |
NSM2019 |
|
0.27 | 5000 | 8.2 | 3.3 | 320 | 1.5 | -40~150 | 1.65 | 26.4 | ±50 | SOW10 | Industrial |
NSM2019-Q0 |
|
Wide current range available AC/DC measurement Conduction resistance as low as 0.27mOhm Support proportional output or fixed output Integrated over-current protection | SOW-10 | 20~200A | 3.3V/5V | 5000Vrms@1min 1618VDC (1144VAC) | 8.2mm/8.2mm | -40℃~150℃ | 320kHz/1.5μs | Automotive OBC, DC/DC, charging gun, PTC heater |
For more product information, please contact us.